Offices in Pembroke Pines FL · Ottawa · Canberra — serving the USA, Canada, UK & AustraliaFree calculatorsFree bid guide (850) 343-4090   info@premiumestimatings.com   WhatsApp
Takeoff guide · Sep 17, 2026 · 4 min read

Plumbing takeoff checklist: fixtures, piping and fittings

A printable plumbing takeoff checklist for commercial projects: fixtures, equipment, underground, waste and vent, domestic water, gas, insulation and testing.

Plumbing takeoff checklist: fixtures, piping and fittings – Premium Estimating LLC guide
Quick answer: A complete plumbing takeoff covers fixtures, equipment, underground sanitary and storm piping, above-ground waste and vent, domestic cold, hot and return water, storm drainage, gas piping, fittings, valves, hangers, insulation, sleeves, firestopping, testing and permits, measured by system, size and material.

Key takeaways

  • Measure each system separately so pricing matches material and labor
  • Add vertical runs from risers and fixture heights
  • Check details and enlarged plans for typical notes
  • Review kitchen, mechanical and civil drawings for connections

A plumbing takeoff is the foundation of every plumbing estimate. If a fixture, a section of underground pipe or a piece of equipment is missed, no amount of careful pricing will fix the bid. This checklist helps plumbing contractors, general contractors and estimators make sure every part of the plumbing scope is captured.

Use it during the takeoff and again as a final review.

Before you start

  • Confirm you have every plumbing sheet, plus architectural, civil, kitchen and mechanical drawings
  • Read the general notes, legends and abbreviations
  • Read Division 22 specifications: pipe materials by system, joint types, insulation, testing
  • Note all addenda and their changes
  • Set and check the scale on each sheet

1. Fixtures

  • Water closets (floor-mounted and wall-hung)
  • Urinals
  • Lavatories and sinks by type
  • Mop and service sinks
  • Showers and tubs
  • Drinking fountains and bottle fillers
  • Emergency eyewash and showers
  • Floor drains, floor sinks and trench drains
  • Hose bibs and wall hydrants
  • Fixture carriers and supports
  • Trim, faucets and flush valves if not included with fixtures

2. Equipment

  • Water heaters (gas, electric, tankless)
  • Recirculation pumps
  • Booster pumps
  • Backflow preventers
  • Expansion tanks
  • Thermostatic mixing valves
  • Grease interceptors and oil separators
  • Water softeners or treatment
  • Sump and sewage ejector pumps

3. Underground sanitary and storm

  • Pipe by size and material
  • Cleanouts
  • Fittings
  • Trenching, bedding and backfill (confirm if by the plumber)
  • Slab cutting and patching on renovations
  • Connection to the site sewer
  • Testing

4. Above-ground waste and vent

  • Waste piping by size
  • Vent piping by size
  • Stacks and through-roof vents
  • Fixture connections and trap arms
  • Fittings and cleanouts

5. Domestic water

  • Cold water by size and material
  • Hot water by size
  • Hot water return
  • Shutoff and balancing valves
  • Water hammer arrestors
  • Meter and main connection
  • Insulation by size

6. Storm drainage

  • Roof drains and overflow drains
  • Conductors and horizontal storm pipe
  • Downspout nozzles
  • Insulation on horizontal storm piping if specified

7. Gas piping

  • Pipe by size and material
  • Valves and regulators
  • Connections to equipment
  • Seismic or excess flow valves if required

8. Hangers, supports and accessories

  • Hangers and rods by spacing
  • Seismic bracing if required
  • Sleeves and firestopping
  • Access panels
  • Pipe identification and labels

9. Testing and closeout

  • Pressure testing
  • Disinfection of domestic water
  • Permits and inspections
  • As-built drawings and O&M manuals

Measuring tips

  • Measure by system. Keep sanitary, vent, domestic water, storm and gas separate so pricing matches materials and labor.
  • Add vertical runs. Fixture rough-in heights, risers and drops add up quickly on multi-story buildings.
  • Use colour. Assign one colour per system in your takeoff software so you can see what is measured.
  • Check details. Interceptors, cleanouts and special connections often appear only in details.
  • Watch typical notes. "Typical of 12" on one enlarged plan can mean twelve times the work.

Final review questions

  • Does every fixture on the schedule appear in the takeoff?
  • Is every room with water use connected?
  • Are underground and above-ground both included?
  • Are kitchen and mechanical connections included?
  • Is insulation included where specified?
  • Are permits and testing included or clearly excluded?

Organizing the takeoff for pricing

A plumbing takeoff is easiest to price when it is organized the same way as the estimate. Group quantities by system, then by pipe material, then by size. Keep underground and above-ground separate because the labor is very different. Count fittings for large sizes and expensive materials, and use an allowance for small fittings. Record which sheet each quantity came from. When an addendum arrives, this structure lets you update only the affected systems instead of starting over, which saves hours on bid day.

From takeoff to estimate

Once the quantities are complete, each line gets material pricing, labor units and markups. Premium Estimating LLC prepares plumbing takeoffs and estimates with every system measured by size and material and a marked-up set of plans. See the format in our plumbing sample estimate.

Need numbers you can bid from? Send us your plans for a quote, see our pricing or download our sample estimates.
FAQ

Common questions

Can't find your answer? Call (850) 343-4090 or email info@premiumestimatings.com.

What is a plumbing takeoff?

A measured and counted list of all plumbing fixtures, equipment, pipe, fittings and accessories on a project, taken from the drawings and specs.

How do you measure pipe in a takeoff?

By system, size and material, measuring horizontal runs on plans and adding vertical lengths from risers, sections and fixture heights.

Should fittings be counted or estimated?

Large or expensive fittings should be counted. Smaller fittings are often estimated as an allowance per length of pipe based on the system type.

Free download: The Commercial Bid Estimating Guide 2026, a printable checklist of commonly missed scope by CSI division. Get the PDF →
Send plans

Send Us the Plans. Get a Quote.

Send your drawings and we'll reply with a price and delivery date before any work starts.

  • Clear price and delivery date up front
  • NDA signed on every project
  • Excel estimate organized by CSI division
  • Marked-up plans showing every quantity
  • 50% to start, 50% on delivery
Prefer email or phone?info@premiumestimatings.com(850) 343-4090

Your details

Upload drawings / plans
Drop files here or click to browsePDF, ZIP, DWG, DXF, XLSX, DOC, JPG · up to 5 files, 8 MB total
    Large plan sets: share a link instead of uploading.

    By sending, you agree to our Privacy Policy.

    Get a Quote Chat on WhatsApp