Sprinkler heads
Heads are counted by type: pendent, upright, sidewall, concealed and dry. Areas without a layout are priced from coverage per head for the hazard classification noted in the specs.
Fire sprinkler and standpipe systems measured from your fire protection drawings: heads, pipe by size, fittings, valves, risers and fire pump equipment priced with material and labor for your market.
Fire protection bids are priced in a market where margins are thin and drawings are often incomplete at bid time. Many bid sets show only a performance specification and a few riser details, while others include full layout drawings from the sprinkler designer. Our fire protection estimating service handles both: we take off what is drawn and, where layouts are not yet designed, we price from area and hazard classification with clear assumptions.
We support fire sprinkler contractors, mechanical contractors who carry Division 21, and general contractors who need an independent number on offices, warehouses, schools, hotels, healthcare and multifamily projects.
Please note that we provide estimating and takeoff only. We do not prepare sprinkler layout design or hydraulic calculations, which remain the responsibility of the licensed sprinkler designer on the project.
Heads are counted by type: pendent, upright, sidewall, concealed and dry. Areas without a layout are priced from coverage per head for the hazard classification noted in the specs.
Pipe is measured by size and material, separating schedule 10, schedule 40 and CPVC, with grooved or threaded fittings priced by size.
System risers, alarm check valves, control valves, flow and tamper switches, inspector test and drain assemblies are listed per riser.
Standpipe risers, hose valves, roof manifolds and fire department connections are measured from riser diagrams.
Fire pumps, controllers, jockey pumps and backflow preventers are priced from equipment schedules and specifications.
Hangers, seismic sway bracing and restraints are calculated per run, which matters in seismic regions on the West Coast.
Common misses are dry systems in unheated areas such as attics, canopies and loading docks, extra heads under obstructions like ducts wider than four feet, and seismic bracing. We look for each of these in the drawings and the specifications.
Other gaps include the underground fire line from the street, the fire department connection, backflow testing, the alarm interface with the fire alarm contractor, and permit and inspection fees. Our assumptions list says what is included so the bid matches your scope letter.
Where layout drawings exist, heads, pipe and fittings are counted directly from them. Where they do not, we calculate protected area by hazard classification, apply head spacing and typical pipe per head, and list these as budget allowances so you can see which quantities are measured and which are allowances.
Material is priced from current supplier pricing and labor from installation units per head and per foot of pipe for your project location, with lifts and equipment shown separately.
Warehouses and distribution centers are dominated by large-diameter mains, ESFR heads and fire pumps, so pipe weight and lift time drive the price. Multifamily projects repeat typical units with residential heads and CPVC, plus attic and balcony protection that is easy to miss. Offices and retail often bid with shell-only layouts and tenant allowances, while hotels and healthcare add standpipes, multiple risers and stricter inspection requirements.
For every type we separate measured quantities from allowances, show heads per area so you can check density, and list the scope split with the plumbing, fire alarm and site contractors. See our warehouse and multifamily estimating pages for more.
Can't find your answer? Call (850) 343-4090 or email info@premiumestimatings.com.
It includes sprinkler heads, pipe and fittings by size, hangers and bracing, risers and valves, standpipes, fire department connections, and fire pumps and backflow where shown, with material and labor priced for the project location.
No. We provide estimating and quantity takeoffs only. Hydraulic calculations and layout design are done by the licensed sprinkler designer.
Yes. We price from protected area, hazard classification and head spacing, and show these lines as allowances with clear assumptions.
Yes. Fire alarm can be priced as its own estimate. See our fire alarm estimating service.
Single-trade estimates start from $300, confirmed in your quote after we review the drawing set.
Send your drawings and we'll reply with a price and delivery date before any work starts.