Structured cabling
Drops are counted by room and outlet type. Cable length uses average run to the serving telecom room, plus slack and service loops, so footage matches how the building is laid out.
Structured cabling, data and voice, access control, CCTV, intrusion, audio-visual and nurse call measured device by device from your technology drawings, with cable, pathway and labor priced for your market.
Low voltage scopes are easy to underestimate because most of the cost is hidden in cable length and labor, not in the devices shown on the plan. A drop symbol on a floor plan becomes cable to the telecom room, a jack, a faceplate, a patch panel port, testing and labeling. Our low voltage estimating service counts every device and converts it into cable, terminations and hours.
We work for low voltage and technology contractors, electrical contractors who carry Division 27 and 28, and general contractors who need a check number for technology packages on offices, schools, healthcare, hotels, multifamily and retail projects.
Send the technology drawings (T-series sheets), the electrical drawings for pathway and power, and the Division 27 and 28 specifications. We return an Excel estimate by system with device counts, cable footage by type, rack and cabinet equipment, and labor, plus marked-up plans.
Drops are counted by room and outlet type. Cable length uses average run to the serving telecom room, plus slack and service loops, so footage matches how the building is laid out.
Racks, cabinets, patch panels, cable management, ladder rack, backboards and grounding busbars are listed per room from the enlarged plans and details.
Fiber and multi-pair copper risers between MDF and IDF rooms are measured by route with terminations, enclosures and testing.
Access control is priced per door with readers, locks, door contacts and request-to-exit devices. Cameras are counted by type with mounts and recording equipment.
Speakers, displays, projectors, input plates and amplifiers are counted from the AV plans, with cable and terminations per device.
J-hooks, sleeves, conduit stubs and firestopping are listed where carried by the low voltage trade. Labor is priced per drop, per device and per termination.
The biggest misses in low voltage bids are cable lengths taken as straight lines, forgotten service loops, and the time to test, label and certify each cable. We use realistic routing with slack, and testing and documentation are listed as their own line.
Other common gaps are firestopping at rated walls, J-hooks and cable supports, grounding and bonding in telecom rooms, owner-furnished equipment that still needs installation, and the division of scope between the electrical contractor and the technology contractor. Our assumptions list states which trade carries conduit, boxes and power to each device, so your bid lines up with the scope sheet.
The takeoff starts with the device legend and symbol counts on each technology sheet, checked against the riser diagrams and the specifications. Cable is then calculated by telecom room service area, and terminations, testing and labeling follow the device count.
Pricing uses current distributor pricing for cable and components and labor units per drop and device for your project location. You can replace our labor rates with your own crew rates, and the Excel file keeps quantities separate from pricing so it is easy to update.
Offices and tenant improvements are driven by workstation drops, conference room AV and access control on suites and stairs. Schools add classroom AV, paging and intercom, clocks and wireless access points in every room. Healthcare projects carry nurse call, real-time location systems and heavy security. Hotels and multifamily repeat a typical unit many times, so one accurate unit takeoff multiplied correctly is the key to the whole bid.
On each type we follow the same rule: count every device on the plan, then build cable, terminations, testing and hours from that count. See our schools, healthcare and multifamily estimating pages for more on those markets.
Can't find your answer? Call (850) 343-4090 or email info@premiumestimatings.com.
A low voltage estimate covers structured cabling, telecom room equipment, backbone, and any security, access control, CCTV, AV, paging or nurse call systems shown on the technology drawings, priced with material and labor for each device and cable run.
Yes. Access control is priced per door and cameras by type, with panels, recorders, cable and labor. If the owner furnishes equipment, we price installation only.
We use the average run from each telecom room to its service area, plus vertical drops, slack and service loops, then multiply by the drop count. Each run category is shown so you can check it.
Yes. Low voltage can be priced as its own package or combined with an electrical estimate, with a clear line between pathway and power and the cabling scope.
Single-trade estimates start from $300, confirmed in your quote after we review the drawing set.
Send your drawings and we'll reply with a price and delivery date before any work starts.